Home
last modified time | relevance | path

Searched full:anomaly (Results 1 – 14 of 14) sorted by relevance

/nrf52832-nimble/nordic/nrfx/
H A DCHANGELOG.md70 - Implemented workaround for nRF52832 and nRF52840 anomaly 194 in the I2S driver.
71 - Implemented workaround for nRF52840 anomaly 195 in the SPIM driver.
94 - Implemented workaround for nRF52840 anomaly 122 in the QSPI driver.
95 - Implemented workaround for nRF52840 anomaly 198 in the SPIM driver.
/nrf52832-nimble/nordic/nrfx/drivers/src/
H A Dnrfx_clock.c64 // Enable workaround for nRF52 anomaly 192 (LFRC oscillator frequency is wrong
68 // Enable workaround for nRF52 anomaly 201 (EVENTS_HFCLKSTARTED might be generated twice).
86 bool hfclk_started; /*< Anomaly 201 workaround. */
106 // ANOMALY 132 - LFCLK needs to avoid frame from 66us to 138us after LFCLK stop. This solution
H A Dnrfx_i2s.c51 // Enable workaround for nRF52832 and nRF52840 anomaly 194 (STOP task does not
342 // RXPTRUPD and TXPTRUPD events (see nRF52 anomaly 55) are processed. in nrfx_i2s_stop()
H A Dnrfx_pwm.c151 // The workaround for nRF52 Anomaly 109 "protects" DMA transfers by handling in nrfx_pwm_init()
208 // The workaround for nRF52 Anomaly 109 "protects" DMA transfers by in start_playback()
H A Dnrfx_spim.c87 // Enable workaround for nRF52840 anomaly 195 (SPIM3 continues to draw current after disable).
120 // Workaround for nRF52840 anomaly 198: SPIM3 transmit data might be corrupted.
/nrf52832-nimble/nordic/nrfx/mdk/
H A Dsystem_nrf51.c60 to enable the use of peripherals" found at Product Anomaly document for your device found at in SystemInit()
71 register is incorrect" found at Product Anomaly document for your device found at in SystemInit()
79 …y PAN 76 "System: Excessive current in sleep mode with retention" found at Product Anomaly document in SystemInit()
/nrf52832-nimble/packages/NimBLE-latest/nimble/drivers/nrf52/
H A Dsyscfg.yml61 Enable workaround for anomaly 164 found in nRF52840.
69 Enable workaround for anomaly 191 found in nRF52840.
/nrf52832-nimble/nordic/nrfx/hal/
H A Dnrf_temp.h58 …/**@note Workaround for PAN_028 rev2.0A anomaly 31 - TEMP: Temperature offset value has to be manu… in nrf_temp_init()
69 …/**@note Workaround for PAN_028 rev2.0A anomaly 28 - TEMP: Negative measured values are not repres… in nrf_temp_read()
H A Dnrf_qspi.h557 // Workaround for nRF52840 anomaly 122: Current consumption is too high. in nrf_qspi_disable()
/nrf52832-nimble/nordic/nrfx/drivers/include/
H A Dnrfx_spis.h159 * @note When the nRF52 Anomaly 109 workaround for SPIS is enabled, this function
178 * only when using nRF52 Anomaly 109 workaround.
H A Dnrfx_nfct.h361 * The current code contains a patch for the anomaly 25 (NFCT: Reset value of
/nrf52832-nimble/drivers/
H A Dnrfx_config.h1174 // <e> NRFX_PWM_NRF52_ANOMALY_109_WORKAROUND_ENABLED - Enables nRF52 Anomaly 109 workaround for PWM.
1187 // <o> NRFX_PWM_NRF52_ANOMALY_109_EGU_INSTANCE - EGU instance used by the nRF52 Anomaly 109 workar…
1758 // <q> NRFX_SPIM_NRF52_ANOMALY_109_WORKAROUND_ENABLED - Enables nRF52 anomaly 109 workaround for S…
1765 // <i> document or Anomaly 109 Addendum located at
1880 // <q> NRFX_SPIS_NRF52_ANOMALY_109_WORKAROUND_ENABLED - Enables nRF52 Anomaly 109 workaround for S…
2361 // <q> NRFX_TWIM_NRF52_ANOMALY_109_WORKAROUND_ENABLED - Enables nRF52 anomaly 109 workaround for T…
2368 // <i> Anomaly 109 Addendum located at https://infocenter.nordicsemi.com/
/nrf52832-nimble/nordic/nrfx/templates/nRF52832/
H A Dnrfx_config.h1174 // <e> NRFX_PWM_NRF52_ANOMALY_109_WORKAROUND_ENABLED - Enables nRF52 Anomaly 109 workaround for PWM.
1187 // <o> NRFX_PWM_NRF52_ANOMALY_109_EGU_INSTANCE - EGU instance used by the nRF52 Anomaly 109 workar…
1758 // <q> NRFX_SPIM_NRF52_ANOMALY_109_WORKAROUND_ENABLED - Enables nRF52 anomaly 109 workaround for S…
1765 // <i> document or Anomaly 109 Addendum located at
1880 // <q> NRFX_SPIS_NRF52_ANOMALY_109_WORKAROUND_ENABLED - Enables nRF52 Anomaly 109 workaround for S…
2361 // <q> NRFX_TWIM_NRF52_ANOMALY_109_WORKAROUND_ENABLED - Enables nRF52 anomaly 109 workaround for T…
2368 // <i> Anomaly 109 Addendum located at https://infocenter.nordicsemi.com/
/nrf52832-nimble/nordic/nrfx/templates/nRF52840/
H A Dnrfx_config.h1879 // <q> NRFX_SPIM3_NRF52840_ANOMALY_198_WORKAROUND_ENABLED - Enables nRF52840 anomaly 198 workaroun…