Lines Matching +full:thermal +full:- +full:zone

1 // SPDX-License-Identifier: GPL-2.0
12 #include <linux/thermal.h>
24 * mul_frac() - multiply two fixed-point numbers
28 * Return: the result of multiplying two fixed-point numbers. The
29 * result is also a fixed-point number.
37 * div_frac() - divide two fixed-point numbers
41 * Return: the result of dividing two fixed-point numbers. The
42 * result is also a fixed-point number.
50 * struct power_actor - internal power information for power actor
66 * struct power_allocator_params - parameters for the power allocator governor
67 * @allocated_tzp: whether we have allocated tzp for this thermal zone and
73 * @sustainable_power: Sustainable power (heat) that this thermal zone can
75 * @trip_switch_on: first passive trip point of the thermal zone. The
77 * If the thermal zone only has one passive trip point,
79 * @trip_max: last passive trip point of the thermal zone. The
81 * @total_weight: Sum of all thermal instances weights
83 * @buffer_size: internal buffer size, to avoid runtime re-calculation
102 return cdev_is_power_actor(instance->cdev); in power_actor_is_valid()
106 * estimate_sustainable_power() - Estimate the sustainable power of a thermal zone
107 * @tz: thermal zone we are operating in
109 * For thermal zones that don't provide a sustainable_power in their
113 * this governor, provide a sustainable_power in the thermal zone's
118 struct power_allocator_params *params = tz->governor_data; in estimate_sustainable_power()
119 const struct thermal_trip_desc *td = trip_to_trip_desc(params->trip_max); in estimate_sustainable_power()
125 list_for_each_entry(instance, &td->thermal_instances, trip_node) { in estimate_sustainable_power()
129 cdev = instance->cdev; in estimate_sustainable_power()
130 if (cdev->ops->state2power(cdev, instance->upper, &min_power)) in estimate_sustainable_power()
140 * estimate_pid_constants() - Estimate the constants for the PID controller
141 * @tz: thermal zone for which to estimate the constants
142 * @sustainable_power: sustainable power for the thermal zone
158 temperature_threshold -= trip_switch_on->temperature; in estimate_pid_constants()
162 * values for thermal zones that don't provide them. If a in estimate_pid_constants()
163 * system integrator has configured a thermal zone with two in estimate_pid_constants()
165 * hasn't put any effort to set up the thermal zone properly in estimate_pid_constants()
171 tz->tzp->k_po = int_to_frac(sustainable_power) / in estimate_pid_constants()
174 tz->tzp->k_pu = int_to_frac(2 * sustainable_power) / in estimate_pid_constants()
177 k_i = tz->tzp->k_pu / 10; in estimate_pid_constants()
178 tz->tzp->k_i = k_i > 0 ? k_i : 1; in estimate_pid_constants()
187 * get_sustainable_power() - Get the right sustainable power
188 * @tz: thermal zone for which to estimate the constants
195 * after thermal zone binding, where the initial values where set to 0.
203 if (!tz->tzp->sustainable_power) in get_sustainable_power()
206 sustainable_power = tz->tzp->sustainable_power; in get_sustainable_power()
209 if (sustainable_power != params->sustainable_power) { in get_sustainable_power()
211 params->trip_switch_on, control_temp); in get_sustainable_power()
214 tz->tzp->sustainable_power = sustainable_power; in get_sustainable_power()
215 params->sustainable_power = sustainable_power; in get_sustainable_power()
222 * pid_controller() - PID controller
223 * @tz: thermal zone we are operating in
225 * @max_allocatable_power: maximum allocatable power for this thermal zone
228 * temperature of the thermal zone gets as close as possible to
243 struct power_allocator_params *params = tz->governor_data; in pid_controller()
252 err = control_temp - tz->temperature; in pid_controller()
256 p = mul_frac(err < 0 ? tz->tzp->k_po : tz->tzp->k_pu, err); in pid_controller()
264 i = mul_frac(tz->tzp->k_i, params->err_integral); in pid_controller()
266 if (err < int_to_frac(tz->tzp->integral_cutoff)) { in pid_controller()
267 s64 i_next = i + mul_frac(tz->tzp->k_i, err); in pid_controller()
271 params->err_integral += err; in pid_controller()
278 * We do err - prev_err, so with a positive k_d, a decreasing in pid_controller()
282 d = mul_frac(tz->tzp->k_d, err - params->prev_err); in pid_controller()
283 d = div_frac(d, jiffies_to_msecs(tz->passive_delay_jiffies)); in pid_controller()
284 params->prev_err = err; in pid_controller()
288 /* feed-forward the known sustainable dissipatable power */ in pid_controller()
294 frac_to_int(params->err_integral), in pid_controller()
302 * power_actor_set_power() - limit the maximum power a cooling device consumes
304 * @instance: thermal instance to update
310 * Return: 0 on success, -EINVAL if the cooling device does not
311 * implement the power actor API or -E* for other failures.
320 ret = cdev->ops->power2state(cdev, power, &state); in power_actor_set_power()
324 instance->target = clamp_val(state, instance->lower, instance->upper); in power_actor_set_power()
332 * divvy_up_power() - divvy the allocated power between the actors
334 * @num_actors: number of power actors in this thermal zone
347 * surplus is re-divvied among the actors based on how far they are
365 pa->granted_power = pa->max_power; in divvy_up_power()
373 u64 req_range = (u64)pa->weighted_req_power * power_range; in divvy_up_power()
375 pa->granted_power = DIV_ROUND_CLOSEST_ULL(req_range, in divvy_up_power()
378 if (pa->granted_power > pa->max_power) { in divvy_up_power()
379 extra_power += pa->granted_power - pa->max_power; in divvy_up_power()
380 pa->granted_power = pa->max_power; in divvy_up_power()
383 pa->extra_actor_power = pa->max_power - pa->granted_power; in divvy_up_power()
384 capped_extra_power += pa->extra_actor_power; in divvy_up_power()
391 * Re-divvy the reclaimed extra among actors based on in divvy_up_power()
398 u64 extra_range = pa->extra_actor_power; in divvy_up_power()
401 pa->granted_power += DIV_ROUND_CLOSEST_ULL(extra_range, in divvy_up_power()
408 struct power_allocator_params *params = tz->governor_data; in allocate_power()
409 const struct thermal_trip_desc *td = trip_to_trip_desc(params->trip_max); in allocate_power()
410 unsigned int num_actors = params->num_actors; in allocate_power()
411 struct power_actor *power = params->power; in allocate_power()
425 memset(power, 0, params->buffer_size); in allocate_power()
427 list_for_each_entry(instance, &td->thermal_instances, trip_node) { in allocate_power()
433 cdev = instance->cdev; in allocate_power()
435 ret = cdev->ops->get_requested_power(cdev, &pa->req_power); in allocate_power()
439 if (!params->total_weight) in allocate_power()
442 weight = instance->weight; in allocate_power()
444 pa->weighted_req_power = frac_to_int(weight * pa->req_power); in allocate_power()
446 ret = cdev->ops->state2power(cdev, instance->lower, in allocate_power()
447 &pa->max_power); in allocate_power()
451 total_req_power += pa->req_power; in allocate_power()
452 max_allocatable_power += pa->max_power; in allocate_power()
453 total_weighted_req_power += pa->weighted_req_power; in allocate_power()
464 list_for_each_entry(instance, &td->thermal_instances, trip_node) { in allocate_power()
470 power_actor_set_power(instance->cdev, instance, in allocate_power()
471 pa->granted_power); in allocate_power()
472 total_granted_power += pa->granted_power; in allocate_power()
474 trace_thermal_power_actor(tz, i, pa->req_power, in allocate_power()
475 pa->granted_power); in allocate_power()
481 max_allocatable_power, tz->temperature, in allocate_power()
482 control_temp - tz->temperature); in allocate_power()
486 * get_governor_trips() - get the two trip points that are key for this governor
487 * @tz: thermal zone to operate on
509 const struct thermal_trip *trip = &td->trip; in get_governor_trips()
511 switch (trip->type) { in get_governor_trips()
528 params->trip_switch_on = first_passive; in get_governor_trips()
529 params->trip_max = last_passive; in get_governor_trips()
531 params->trip_switch_on = NULL; in get_governor_trips()
532 params->trip_max = first_passive; in get_governor_trips()
534 params->trip_switch_on = NULL; in get_governor_trips()
535 params->trip_max = last_active; in get_governor_trips()
541 params->err_integral = 0; in reset_pid_controller()
542 params->prev_err = 0; in reset_pid_controller()
547 struct power_allocator_params *params = tz->governor_data; in allow_maximum_power()
548 const struct thermal_trip_desc *td = trip_to_trip_desc(params->trip_max); in allow_maximum_power()
553 list_for_each_entry(instance, &td->thermal_instances, trip_node) { in allow_maximum_power()
557 cdev = instance->cdev; in allow_maximum_power()
559 instance->target = 0; in allow_maximum_power()
566 cdev->ops->get_requested_power(cdev, &req_power); in allow_maximum_power()
568 if (params->update_cdevs) in allow_maximum_power()
575 * check_power_actors() - Check all cooling devices and warn when they are
577 * @tz: thermal zone to operate on
586 * devices may be attached later). Otherwise, return -EINVAL.
595 if (!params->trip_max) in check_power_actors()
598 td = trip_to_trip_desc(params->trip_max); in check_power_actors()
600 list_for_each_entry(instance, &td->thermal_instances, trip_node) { in check_power_actors()
601 if (!cdev_is_power_actor(instance->cdev)) { in check_power_actors()
602 dev_warn(&tz->device, "power_allocator: %s is not a power actor\n", in check_power_actors()
603 instance->cdev->type); in check_power_actors()
604 return -EINVAL; in check_power_actors()
617 kfree(params->power); in allocate_actors_buffer()
625 params->power = kcalloc(num_actors, sizeof(struct power_actor), in allocate_actors_buffer()
627 if (!params->power) { in allocate_actors_buffer()
628 ret = -ENOMEM; in allocate_actors_buffer()
632 params->num_actors = num_actors; in allocate_actors_buffer()
633 params->buffer_size = num_actors * sizeof(struct power_actor); in allocate_actors_buffer()
638 params->num_actors = 0; in allocate_actors_buffer()
639 params->buffer_size = 0; in allocate_actors_buffer()
640 params->power = NULL; in allocate_actors_buffer()
649 if (!params->trip_max) in power_allocator_update_weight()
652 td = trip_to_trip_desc(params->trip_max); in power_allocator_update_weight()
654 params->total_weight = 0; in power_allocator_update_weight()
655 list_for_each_entry(instance, &td->thermal_instances, trip_node) in power_allocator_update_weight()
657 params->total_weight += instance->weight; in power_allocator_update_weight()
663 struct power_allocator_params *params = tz->governor_data; in power_allocator_update_tz()
664 const struct thermal_trip_desc *td = trip_to_trip_desc(params->trip_max); in power_allocator_update_tz()
671 list_for_each_entry(instance, &td->thermal_instances, trip_node) in power_allocator_update_tz()
675 if (num_actors != params->num_actors) in power_allocator_update_tz()
688 * power_allocator_bind() - bind the power_allocator governor to a thermal zone
689 * @tz: thermal zone to bind it to
691 * Initialize the PID controller parameters and bind it to the thermal
692 * zone.
694 * Return: 0 on success, or -ENOMEM if we ran out of memory, or -EINVAL
704 return -ENOMEM; in power_allocator_bind()
710 dev_warn(&tz->device, "power_allocator: binding failed\n"); in power_allocator_bind()
717 dev_warn(&tz->device, "power_allocator: allocation failed\n"); in power_allocator_bind()
722 if (!tz->tzp) { in power_allocator_bind()
723 tz->tzp = kzalloc(sizeof(*tz->tzp), GFP_KERNEL); in power_allocator_bind()
724 if (!tz->tzp) { in power_allocator_bind()
725 ret = -ENOMEM; in power_allocator_bind()
729 params->allocated_tzp = true; in power_allocator_bind()
732 if (!tz->tzp->sustainable_power) in power_allocator_bind()
733 dev_warn(&tz->device, "power_allocator: sustainable_power will be estimated\n"); in power_allocator_bind()
735 params->sustainable_power = tz->tzp->sustainable_power; in power_allocator_bind()
737 if (params->trip_max) in power_allocator_bind()
738 estimate_pid_constants(tz, tz->tzp->sustainable_power, in power_allocator_bind()
739 params->trip_switch_on, in power_allocator_bind()
740 params->trip_max->temperature); in power_allocator_bind()
744 tz->governor_data = params; in power_allocator_bind()
751 kfree(params->power); in power_allocator_bind()
759 struct power_allocator_params *params = tz->governor_data; in power_allocator_unbind()
761 dev_dbg(&tz->device, "Unbinding from thermal zone %d\n", tz->id); in power_allocator_unbind()
763 if (params->allocated_tzp) { in power_allocator_unbind()
764 kfree(tz->tzp); in power_allocator_unbind()
765 tz->tzp = NULL; in power_allocator_unbind()
768 kfree(params->power); in power_allocator_unbind()
769 kfree(tz->governor_data); in power_allocator_unbind()
770 tz->governor_data = NULL; in power_allocator_unbind()
775 struct power_allocator_params *params = tz->governor_data; in power_allocator_manage()
776 const struct thermal_trip *trip = params->trip_switch_on; in power_allocator_manage()
778 lockdep_assert_held(&tz->lock); in power_allocator_manage()
780 if (trip && tz->temperature < trip->temperature) { in power_allocator_manage()
783 params->update_cdevs = false; in power_allocator_manage()
787 if (!params->trip_max) in power_allocator_manage()
790 allocate_power(tz, params->trip_max->temperature); in power_allocator_manage()
791 params->update_cdevs = true; in power_allocator_manage()