Lines Matching +full:2 +full:khz
92 The LM85 uses the 2-wire interface compatible with the SMBUS 2.0
108 transistor like the 2N3904.
133 for 3-wire and 2-wire mode. For this reason, the 2-wire fan modes are not
153 driven by a 22.5 kHz clock. This is a global mode, not per-PWM output,
154 which means that setting any PWM frequency above 11.3 kHz will switch
155 all 3 PWM outputs to a 22.5 kHz frequency. Conversely, setting any PWM
156 frequency below 11.3 kHz will switch all 3 PWM outputs to a frequency
179 The LM96000 supports additional high frequency PWM modes (22.5 kHz, 24 kHz,
180 25.7 kHz, 27.7 kHz and 30 kHz), which can be configured on a per-PWM basis.
213 sensors and therefore three zones (# 1, 2 and 3). Each zone has the following
261 2 Controlled by Zone 2
263 23 Controlled by higher temp of Zone 2 or 3
264 123 Controlled by highest temp of Zone 1, 2 or 3
267 -2 Manual control (write to 'pwm#' to set)