Lines Matching +full:input +full:- +full:hysteresis
14 https://www.analog.com/static/imported-files/data_sheets/ADT7410.pdf
23 https://www.analog.com/static/imported-files/data_sheets/ADT7420.pdf
33 https://www.analog.com/static/imported-files/data_sheets/ADT7310.pdf
43 https://www.analog.com/static/imported-files/data_sheets/ADT7320.pdf
48 -----------
51 -55°C to +150°C. It has a high accuracy of +/-0.5°C and can be operated at a
56 common hysteresis of 0°C - 15°C and a fault queue, ranging from 1 to 4 events.
57 Both pins can individually set to be active-low or active-high, while the whole
64 package, a slightly narrower operating temperature range (-40°C to +150°C), and
72 -------------------
74 Since the device uses one hysteresis value, which is an offset to minimum,
77 hysteresis.
80 sysfs-Interface
81 ---------------
84 temp#_input temperature input
88 temp#_min_hyst hysteresis for temperature minimum (read-only)
89 temp#_max_hyst hysteresis for temperature maximum (read/write)
90 temp#_crit_hyst hysteresis for critical temperature (read-only)