Lines Matching +full:maximum +full:- +full:speed

16 		The contents of the label are free-form.
110 Historical maximum voltage
135 this voltage channel is being used for, and user-space
137 user-space.
145 When disabled the sensor read will return -ENODATA.
147 - 1: Enable
148 - 0: Disable
156 - 1: Failed
157 - 0: Ok
194 Maximum rated voltage.
210 Fan maximum value
235 affects the measurable speed range, not the read value.
256 Desired fan speed
262 Only makes sense if the chip supports closed-loop fan speed
263 control based on the measured fan speed.
272 this fan channel is being used for, and user-space doesn't.
273 In all other cases, the label is provided by user-space.
281 When disabled the sensor read will return -ENODATA.
283 - 1: Enable
284 - 0: Disable
292 - 1: Failed
293 - 0: Ok
309 Fan speed control method:
311 - 0: no fan speed control (i.e. fan at full speed)
312 - 1: manual fan speed control enabled (using `pwmY`)
313 - 2+: automatic fan speed control enabled
322 - 0: DC mode (direct current)
323 - 1: PWM mode (pulse-width modulation)
352 Number of trip points is chip-dependent. Use this for chips
363 Number of trip points is chip-dependent. Use this for chips
376 - 1: CPU embedded diode
377 - 2: 3904 transistor
378 - 3: thermal diode
379 - 4: thermistor
380 - 5: AMD AMDSI
381 - 6: Intel PECI
395 Maximum temperature alarm flag.
397 - 0: OK
398 - 1: temperature has reached tempY_max
414 - 0: OK
415 - 1: temperature has reached tempY_min
461 - 0: OK
462 - 1: temperature has reached tempY_crit
491 - 0: OK
492 - 1: temperature has reached tempY_emergency
543 this temperature channel is being used for, and user-space
545 user-space.
559 Historical maximum temperature
581 When disabled the sensor read will return -ENODATA.
583 - 1: Enable
584 - 0: Disable
598 Maximum rated temperature.
662 Historical maximum current
682 When disabled the sensor read will return -ENODATA.
684 - 1: Enable
685 - 0: Disable
699 Maximum rated current.
725 Maximum power use averaging interval
741 Historical average maximum power use
785 Historical maximum power use
838 Maximum cap that can be set.
854 Maximum power.
862 Critical maximum power.
878 -ENODATA.
880 - 1: Enable
881 - 0: Disable
895 Maximum rated power.
914 -ENODATA.
916 - 1: Enable
917 - 0: Disable
925 - 0: OK
926 - 1: Humidity limit has been reached
935 -ENODATA.
937 - 1: Enable
938 - 0: Disable
946 - 1: Failed
947 - 0: Ok
955 Unit: milli-percent (per cent mille, pcm)
966 this humidity channel is being used for, and user-space
968 user-space.
976 Unit: milli-percent (per cent mille, pcm)
982 Maximum humidity detection
984 - 0: OK
985 - 1: Maximum humidity detected
993 Unit: milli-percent (per cent mille, pcm)
1004 Unit: milli-percent (per cent mille, pcm)
1012 - 0: OK
1013 - 1: Minimum humidity detected
1021 Unit: milli-percent (per cent mille, pcm)
1032 Unit: milli-percent (per cent mille, pcm)
1038 Maximum rated humidity.
1040 Unit: milli-percent (per cent mille, pcm)
1049 - 0: OK
1050 - 1: intrusion detected
1063 - 0: disable
1064 - 1: enable
1072 - 0, off, n: disable
1073 - 1, on, y: enable